Midwest Control Logo                                                                                           Midwest Control Phone 1-800-304-5599


UNLOADER PILOT VALVES, VENTING STYLE

Piloted Unloader Valves are Used in Constant Speed Applications Where There are No Intake Unloaders Present. They Incorporate a Discharge Unloader on the Body of a Pilot Valve to Allow One Valve to Sense System Pressure and Vent Discharge Air to Atmosphere. At Load Pressure, the Pilot Valve Closes the Discharge Unloader and the Compressor Returns to Normal Operation.

Piloted Unloader Valves Require a Separate Check Valve from Which a Line Must be Run to the Discharge Inlet.

Optional Muffler Kit Part No. BG-M-Kit Available for BG Series Direct Unported Pilot Valves

Part No.

Cut In

Cut Out

Discharge Inlet

Pilot Inlet

Vent

Stem

SCFM Capacity

PILOT VALVE WITH HAND UNLOADER, COMPRESSION  DISCHARGE  1/4 C x 1/4 M

BG1-HU195-115

95

115

1/4
Compression 

1/4
Male   

Direct
Unported   

Hand
Unloader   

20   

BG1-HU145-175

145

175

 

PILOT VALVE WITH HAND UNLOADER, FEMALE  DISCHARGE     1/4 F x 1/4 M

BG2-HU95-115

95

115

1/4
 Female    

1/4
Male    

Direct
Unported    

Hand
Unloader   

20   

BG2-HU145-175

145

175

 

PILOT VALVE WITH DUAL CONTROL FEMALE DISCHARGE    1/4 F x 1/4 M

BE2-145-175

110

135

1/4
 Female  

1/4
 Male  

Direct
 Unported  

Dual
 Control

20

 

PILOT VALVE WITH DUAL CONTROL COMPRESSION DISCHARGE   1/4 C  x  1/4 M

BE1-110-135

110

135

1/4
Compression   

1/4
 Male   

Direct
 Unported   

Dual
 Control   

20   

 

HIGH FLOW PILOT VALVE WITH HAND UNLOADER  FEMALE DISCHARGE  1/2 F x 1/4 F

BLG-HU95-115

95

115

1/2
 Female

1/4
Female

1/2
 Female

Hand
Unloader

60

BLG-HU145-175

145

175

BG-M-KIT
Muffler Kit for Direct Unported Pilot Valves

 

  • Construction:  Forged Brass Body, Stainless Steel Spring, and Pilot Ball Valve, 15% Glass Filled Teflon Unloader 
  • Maximum Temperature: 450ºF
    (BLE                               500ºF)
  • Field Adjustable
  • Minimum Cut- In Pressure: 40 PSI
  • Maximum Cut- Out Pressure: 250 PSI

          Dual Control   -   Hand Unloader

  • The Hand Unloader is Typically Used to Manually Unload the Compressor

  • Dual Control is Typically Used on Electric Compressors to Select From  Stop Start to Constant Speed Operation

MCP25CDCV Unloader Pilot Valve Venting Style Conrader
BE1

Unloader Pilot Valve Venting Graphic

Typical Connections
Discharge Exhaust Unported

return to top